RAGIL, DAMA SAPUTRA (2018) OPTIMALISASI PERAWATAN SYSTEM REFRIGERATOR GUNA MENINGKATKAN PROSES PENDINGINAN BAHAN MAKANAN DI VLGC NS CHALLENGER. Diploma thesis, POLITEKNIK ILMU PELAYARAN SEMARANG.
|
Text
06. HALAMAN PERSEMBAHAN .PDF Download (4MB) | Preview |
|
|
Text
07. KATA PENGANTAR.PDF Download (4MB) | Preview |
|
|
Text
08. DAFTAR ISI.PDF Download (4MB) | Preview |
|
|
Text
09. DAFTAR TABEL .PDF Download (4MB) | Preview |
|
|
Text
13. ABSTRACTION.PDF Download (4MB) | Preview |
|
Text
16. BAB III REFRIGERATOR.PDF Restricted to Registered users only Download (4MB) | Request a copy |
||
|
Text
10. DAFTAR GAMBAR.PDF Download (4MB) | Preview |
|
|
Text
14. BAB I REFRIGERATOR .PDF Download (4MB) | Preview |
|
|
Text
12. ABSTRAKSI.PDF Download (4MB) | Preview |
|
|
Text
15. BAB II REFRIGERATOR.PDF Download (4MB) | Preview |
|
Text
17. BAB IV REFRIGERATOR.PDF Restricted to Registered users only Download (5MB) | Request a copy |
||
|
Text
18. BAB V REFRIGERATOR.PDF Download (4MB) | Preview |
|
|
Text
11. DAFTAR LAMPIRAN.PDF Download (4MB) | Preview |
|
|
Text
20. SHIP PARTICULAR.PDF Download (7MB) | Preview |
|
|
Text
19. DAFTAR PUSTAKA.PDF Download (4MB) | Preview |
|
|
Text
21. CREWLIST.PDF Download (5MB) | Preview |
|
|
Text
22. LAMPIRAN WAWANCARA KKM.PDF Download (4MB) | Preview |
|
|
Text
24. GAMBAR 1.PDF Download (4MB) | Preview |
|
|
Text
23. LAMPIRAN WAWANCARA MASINIS 1.PDF Download (4MB) | Preview |
|
|
Text
25. GAMBAR 2.PDF Download (4MB) | Preview |
|
|
Text
27. GAMBAR 4.PDF Download (4MB) | Preview |
|
|
Text
26. GAMBAR 3.PDF Download (4MB) | Preview |
|
|
Text
28. GAMBAR 5.PDF Download (4MB) | Preview |
|
|
Text
29. LEMBAR KONSULTASI PEM 1.PDF Download (4MB) | Preview |
|
|
Text
31. LEMBAR KONSULTASI 2.PDF Download (4MB) | Preview |
|
|
Text
30. LEMBAR KONSULTASI PEM 2.PDF Download (4MB) | Preview |
|
|
Text
32. DAFTAR RIWAYAT HIDUP.PDF Download (4MB) | Preview |
|
|
Text
0. HALAMAN SAMPUL DEPAN.PDF Download (4MB) | Preview |
|
|
Text
01. HALAMAN JUDUL.PDF Download (4MB) | Preview |
|
|
Text
02. LEMBAR PERSETUJUAN.PDF Download (4MB) | Preview |
|
|
Text
03. HALAMAN PENGESAHAN.PDF Download (4MB) | Preview |
|
|
Text
04. HALAMAN PERNYATAAN.PDF Download (4MB) | Preview |
|
|
Text
05. HALAMAN MOTTO.PDF Download (4MB) | Preview |
Abstract
Ragil Dama Saputra, 2018, 50135037. T, “Optimization of Refrigerator System Maintenance to Improve Food Cooling Process On VLGC NS Challenger”, 1st Supervisor : Achmad Wahyudiono, M.M., M.Mar.E. 2nd Supervisor : Capt. H. Agus Subardi, M.Mar. On every ship , to support the smooth running of operational there needs to be a cooling machine. By the presence of cooling machine material food can be stored with whether a time of relative longer than usual in the absence of the persons concerned if stored cooling. With room temperature conditioning in which a controlled be able to constrained the development of the bacteria in of groceries to be causing the occurrence of decay . To support the process storage and preservation food required of machine cooling is a machine cooling must be in good condition. With provisions for storing fruits and vegetables to be fresh required room temperature between 40C until 10oC and for a room of meat and fish should be able to provide temperature between -120C until -18oC. Basic cooling main engines is room temperature cooling desirable must be achieved. There are many obstacles to cause a cool room out to not cold. One of the requirements so that a machine a coolant can work well is circulation of the freon can not be impaired . If the circulation of the stopped in some areas in of the freon would cause the animal to an annual production capacity of evaporation of the ingredients of a a coolant in the evaporators will also the inherited syndromes characterized cause to rooms which they rent out a coolant not capable of temperature is reached cooling of that which is desirable. There is so many things causes disruption of the circulation of the of the freon , and among the companies were: The circulate of lubricant oil in to the freon can hamper the flow of freon in a capillary pipe. Freon leakage can decrease the amount of freon in the system. The unclean condenser can decrease the amount of the freon. If the harassments are not immediately overtake will be very endanger. The handling in Instruction Manual Book should be done consistenly and arranged daily, weekly, quarterly, and annually. In addition, engineer to quickly and respond if there is a disorder work on a cooling. One more thing that should not be forgotten is the crew must always maintaining good relations with the ship owner. The role of company here is in the delivery of spare parts and energy expert technician from shore person if necessary. In this case a request for spare parts must be structured and well-planned. Keywords: Cooler, Circulation, Leakage
Item Type: | Thesis (Diploma) |
---|---|
Uncontrolled Keywords: | Cooler, Circulation, Leakage |
Subjects: | Skripsi > Teknika |
Divisions: | Teknika |
Depositing User: | Users 4 not found. |
Date Deposited: | 30 Jan 2019 02:02 |
Last Modified: | 30 Jan 2019 02:02 |
URI: | http://repository.pip-semarang.ac.id/id/eprint/551 |
Actions (login required)
View Item |