PURNOMO, AGUNG SUDRAJAT (2017) OPTIMALISASI PENANGGULANGAN KEBOCORAN PADA SLUDGE TANK GUNA MENGHINDARI KERUSAKAN MUATAN DALAM CONTAINER DI MV. CTP HONOUR. Diploma thesis, POLITEKNIK ILMU PELAYARAN SEMARANG.
|
Text
Halaman Persembahan.pdf Download (4MB) | Preview |
|
|
Text
Kata Pengantar1.pdf Download (4MB) | Preview |
|
|
Text
Halaman Pengesahan.pdf Download (4MB) | Preview |
|
|
Text
LAMPIRAN II.pdf Download (4MB) | Preview |
|
|
Text
LAMPIRAN I.pdf Download (4MB) | Preview |
|
|
Text
Halaman Persetujuan.pdf Download (4MB) | Preview |
|
|
Text
LAMPIRAN IV.pdf Download (4MB) | Preview |
|
|
Text
Kata Pengantar 2.pdf Download (4MB) | Preview |
|
|
Text
Motto.pdf Download (4MB) | Preview |
|
|
Text
Halaman Pernyataan.pdf Download (4MB) | Preview |
|
|
Text
BAB 1.pdf Download (4MB) | Preview |
|
|
Text
LAMPIRAN III.pdf Download (4MB) | Preview |
|
|
Text
Abstraksi.pdf Download (4MB) | Preview |
|
|
Text
Abstract.pdf Download (4MB) | Preview |
|
|
Text
BAB II.pdf Download (4MB) | Preview |
|
Text
BAB III.pdf Restricted to Registered users only Download (4MB) | Request a copy |
||
|
Text
BAB V.pdf Download (4MB) | Preview |
|
Text
BAB IV .pdf Restricted to Registered users only Download (4MB) | Request a copy |
||
|
Text
Daftar Gambar.pdf Download (4MB) | Preview |
|
|
Text
Daftar Isi.pdf Download (4MB) | Preview |
|
|
Text
Daftar Tabel.pdf Download (4MB) | Preview |
|
|
Text
Halaman Judul.pdf Download (60kB) | Preview |
|
|
Text
Daftar Pustaka.pdf Download (4MB) | Preview |
|
|
Text
Daftar Riwayat Hidup.pdf Download (4MB) | Preview |
Abstract
Purnomo Agung S, NIT. 50134885.N, 2017 : “Optimalization of Leakage Response On Sludge Tank To Avoid Damage Cargo In Container in MV. CTP Honour”, Diploma Program IV, Nautical Studies Program, Politeknik Ilmu Pelayaran Semarang, Supervisor I: Capt. H. Moh. Aziz Rohman, MM, M. Mar, Supervisor II: Okvita Wahyuni, S.ST, MM Sludge tank is something to accommodate dirty oils separated by OWS (Oil Water Separator) against sewer water minimum capacity 2% of tank volume. Sludge from the clarifier settling tank (CST) is pumped into a sludge tank by passing through the desander to remove the fine sands of the sludge. The cleanliness of the oil liquid in the sludge tank is influenced by the operation of the desander, as it can function when the sand drainage is carried out continuously. Theoretical basis in writing this thesis is based on the problems that often arise on the ship. Writing thesis entitled "Optimalization of leakage response on sludge tank to avoid damage cargo in container in MV. CTP Honour "is in order to cope as well as to determine the cause of leaks in sludge tanks that cause damage to the charge in the hold. In this thesis, the writter presents USG method (urgent, seriousness, growth). The research data obtained from the primary data and secondary data, while the method of collecting data obtained from observation, interview, documentation and bibliography. In research on the causes and how to cope with leaks in sludge tanks that cause damage to the loads in the hold. Leaks in the sludge tank are known 2 days after the vessel departs from the port so that the loads submerged in the hold are mostly damaged and the company suffers losses. The results of research and data processing, the writter can conclude that the main cause of leakage in sludge tank is minim maintenance on the pump bilges, holds and sludge tanks. So to cope with leaks in the sludge tank needs to be done more care to pump bilges, holds, and tank or sludge tank. Keywords: Optimalization, Sludge Tank, Cargo.
Item Type: | Thesis (Diploma) |
---|---|
Uncontrolled Keywords: | Optimalization, Sludge Tank, Cargo. |
Subjects: | Skripsi > Nautika |
Divisions: | Nautika |
Depositing User: | Admin Admin Admin |
Date Deposited: | 25 Jan 2019 07:31 |
Last Modified: | 06 Feb 2019 01:09 |
URI: | http://repository.pip-semarang.ac.id/id/eprint/227 |
Actions (login required)
View Item |