ANALISIS TERJADINYA BLACK OUT PADA DIESEL GENERATOR DI MT. MINAS

FATHUBA, BIMAYAKFIKA (2020) ANALISIS TERJADINYA BLACK OUT PADA DIESEL GENERATOR DI MT. MINAS. Diploma thesis, POLITEKNIK ILMU PELAYARAN SEMARANG.

[img] Pdf (52155712T_SKRIPSI_FULLTEXT)
52155712T_SKRIPSI_FULLTEXT.pdf
Restricted to Repository staff only

Download (4MB) | Request a copy
[img] Pdf (52155712T_SKRIPSI_OPEN_ACCESS)
52155712T_SKRIPSI_OPEN_ACCESS.pdf

Download (3MB)
Official URL: http://www.library.pip-semarang.ac.id

Abstract

INTISARI Fathuba Bimayakfika, 2020, NIT : 52155712.T, “Analisis Terjadinya Black out Pada Diesel Generator Di MT. Minas”, skripsi Program Studi Teknika, Progran Diploma IV, Politeknik Ilmu Pelayaran Semarang, Pembimbing I: Dwi Prasetyo, M.M, M.Mar.E. dan Pembimbing II: Dr., Winarno, S.ST, M.H Diesel generator berfungsi mengubah tenaga mekanis menjadi tenaga listrik arus bolak-balik. Arus bolak-balik sering juga di sebut sebagai Alternator, Generator AC (Alternating Current) atau generator sinkron. Dikatakan generator sinkron karna jumlah putaran rotornya sama dengan jumlah putaran medan magnet pada stator. Kecepatan sinkron ini di hasilkan dari kecepatan putaran rotor dengan kutub-kutub magnet yang berputar dengan kecepatan yang sama dengan medan putar pada stator. Mesin ini tidak dapat di jalankan sendiri karena karena kutub-kutub rotor tidak dapat tiba-tiba mengikuti kecepatan medan putar pada waktu saklar penghubung dengan jala-jala generator arus bolak-balik. Jenis metode penelitian yang peneliti gunakan dalam penyusunan skripsi ini adalah deskriptif kualitaf dengan menggunakan pendekatan fishbone analysis dan SHELL untuk mempermudah dalam teknik analisis data. Peneliti juga menggunakan metode pengumpulan data yang peneliti lakukan adalah dengan cara observasi, dokumentasi dan wawancara untuk memperkuat dalam analisis data dan pembahasan. Tujuan dari penelitian ini adalah untuk mengetahui faktor penyebab terjadinya black out pada diesel generator, dampak dari faktor penyebab terjadinya black out pada diesel generator dan upaya yang dilakukan untuk mencegah faktor penyebab terjadinya black out pada diesel generator di MT. Minas. Berdasarkan hasil penelitian peneliti, dapat disimpulkan bahwa faktor penyebab terjadinya black out pada diesel generator di MT. Minas adalah, 1) perawatan tidak terlaksana akibat tidak berjalanya DO Purifier. Dampak yang ditimbulkan adalah 1) ketidaknormalan DO Purifier karena tidak terlaksananya perawatan. Upaya mencegah terjadinya black out pada diesel generator yang harus dilakukan adalah dengan, 1) melaksanakan perawatan DO Pirifier sesuai dengan PMS, melakukan perbaikan ataupun penggantian terhadap komponen DO Purifier yang rusak dengan melakukan overhaul. ABSTRACT Fathuba Bimayakfika, 2020, NIT: 52155712.T, "Analysis of the Black Out Occurrence of Diesel Generators in MT. Minas ", thesis of Engineering Study Program, Diploma IV Program, Semarang Shipping Polytechnic, Advisor I: Dwi Prasetyo, M.M, M.Mar.E. and Advisor II: Dr., Winarno, S.ST, M.H. Diesel generator functions to convert mechanical power into alternating current electric power. Alternating current is often also referred to as Alternator, AC Generator (Alternating Current) or synchronous generator. It is said to be a synchronous generator because the number of rotations of the rotor is the same as the number of rotations of the magnetic field on the stator. This synchronous speed is produced from the rotational speed of the rotor with the magnetic poles rotating at the same speed as the rotating field on the stator. This machine cannot be operated alone because the rotor poles cannot suddenly follow the speed of the rotating field at the time of the connecting switch with alternating current generator grids. The type of research method used by researchers in the preparation of this thesis is descriptive quality using fishbone analysis and SHELL approaches to facilitate data analysis techniques. Researchers also use data collection methods that researchers do is by observation, documentation and interviews to strengthen the data analysis and discussion. The purpose of this study was to determine the factors causing black outs on diesel generators, the impact of the factors causing black outs on diesel generators and efforts made to prevent the causes of black outs on diesel generators in MT. Minas. . Based on the research results of researchers, it can be concluded that the factors causing the black out of diesel generators in MT. Minas is, 1) maintenance is not carried out due to DO not run Purifier. The impact is 1) DO Purifier abnormalities due to not implementing the treatment. Efforts to prevent black outs on diesel generators that must be done are by, 1) carrying out DO Pirifier maintenance in accordance with PMS, repairing or replacing damaged DO Purifier components by overhauling.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Kata kunci : diesel generator, DO Purifier, black out, fishbone, SHELL Keywords: diesel generator, DO Purifier, black out, fishbone, SHELL
Subjects: Skripsi > Teknika
Divisions: Teknika
Depositing User: Unnamed user with email perpustakaan@pip-semarang.ac.id
Date Deposited: 14 Aug 2020 07:22
Last Modified: 14 Aug 2020 07:22
URI: http://repository.pip-semarang.ac.id/id/eprint/2546

Actions (login required)

View Item View Item