WASIS, NOVEBAR ARMANAH (2019) IDENTIFIKASI HIGH WATER LEVEL ALARM PADA SEWAGE TRATMENT PLANT YANG TERUS MENERUS BERBUNYI DI KM. PUSRI INDONESIA 1 SKRIPSI. Diploma thesis, POLITEKNIK ILMU PELAYARAN SEMARANG.
Pdf (52155729T_SKRIPSI_OPEN_ACCESS)
52155729T_Open_Access.pdf Download (4MB) |
|
Pdf (52155729T_SKRIPSI_FULLTEXT)
52155729T_Skripsi_Fulltext.pdf Restricted to Repository staff only Download (4MB) | Request a copy |
Abstract
ABSTRAKSI Wasis Novebar Armanah, NIT. 52155729.T, 2018 “Identifikasi high water level alarm pada Sewage Treatment Plant yang terus menerus berbunyi di KM. Pusri Indonesia 1”, Program Diploma IV, Teknika, Politeknik Ilmu Pelayaran Semarang, Pembimbing I: H. Amad Narto, M.Pd, M.Mar.E dan Pembimbing II: Andy Wahyu Hermanto, MT Sewage Treatment Plant merupakan salah satu sistem permesinan bantu yang digunakan untuk memproses limbah atau kotoran manusia di atas kapal agar limbah tersebut dapat dibuang ke laut dan tidak menimbulkan pencemaran lingkungan laut. Latar belakang penulisan skripsi ini adalah terjadinya high water level alarm yang terus menerus pada Sewage Treatment Plant, sehingga air limbah pada Sewage Treatment Plant keluar melalui over flow. Rumusan masalah pada penelitian ini adalah bagaimana prinsip kerja high water level alarm pada Sewage Treatment Plant?, apakah akibat yang timbul dari high water level alarm yang tidak bekerja dengan baik? dan apakah upaya apa yang dilakukan untuk mengatasi masalah sewage treatment plant agar bekerja dengan normal? Penelitian skripsi ini menggunakan metode fishbone analysis dan fault tree analysis (FTA) dalam menyelesaikan masalah. Menggunakan metode fishbone didapatkan empat faktor penyebab high water level yaitu faktor mesin, metode, manusia dan material. Menggunakan FTA penulis mengidentifakasi faktor tersebut menjadi dua faktor yaitu mesin dan material. Top event dari masalah high water level alarm pada sewage treatment plant yaitu penyumbatan probe level dan penyumbatan impeller discharge pump. Resiko yang ditimbulkan dari adanya penyumbatan pada probe level dan impeller discharge pump pada Sewage Treatment Plant yaitu terjadinya high water level alarm yang terus menerus dan menyebabkan Sewage Treatment Plant bekerja tidak optimal, yang ditandai dengan keluarnya air limbah melalui over flow yang menyebabkan terjadinya luapan air pada dirty water tank. Metode perawatan Sewage Treatment Plant harus dilakukan dengan baik dan teratur sesuai dengan plan maintenance system yang telah diprogramkan agar kerusakan pada Sewage Treatment Plant dapat dihindari. ABSTRACT Wasis Novebar Armanah, NIT. 52155729.T, 2019 "Identification the continuously alarm high water level of Sewage Treatment Plant at MV. Pusri Indonesia 1”, Diploma IV Programe, Technical, Politeknik Ilmu Pelayaran Semarang, Supervisor I: H. Amad Narto, M.Pd, M.Mar.E and Supervisor II: Andy Wahyu Hermanto, MT Sewage Treatment Plant is one of the auxiliary machinery systems used to process sewage or human waste on board so that waste can be discharged into the sea and does not cause pollution of the marine environment. The background of this thesis is the continuously alarm high water level of Sewage Treatment Plant, so that the waste water from Sewage Treatment Plant through over flow. Formulation of the problem in this study is how the water sensor of Sewage Treatment Plant work?, What the effect that arise from high water level alarm which is not working properly? and whether efforts to resolve the problem so Sewage Treatment Plant is working normally? The method used by the writer is fishbone analysis and fault tree analysis. Factor that the writer find from fishbone analysis is material, method, machine, and man. Use fault tree analysis the writer identification two factor, it is machine and material. The top event from the problem which make alarm of high water level in Sewage Treatment Plant is the probe level gagged by the trash and the impeller of discharge pump gagged by the trash. The conclusion of this study is the risk arising from the clogging of probe level and discharge pump’s impeller at Sewage Treatment Plant is continuously alarm high water level and causes Sewage Treatment Plant works not optimal, it is characterized by the discharge of waste water through over flow that makes flotation of waste water in dirty water tank. Maintenance of Sewage Treatment Plant should be done properly and regularly in accordance with the plan maintenance system that has been programmed so that damage to the Sewage Treatment Plant can be avoided.
Item Type: | Thesis (Diploma) |
---|---|
Uncontrolled Keywords: | Kata kunci : Identifikasi, high water level alarm, Sewage Treatment Plant, KM. Pusri Indonesia 1 Keywords: Identification, high water level alarm, Sewage Treatment Plant, MV. Pusri Indonesia 1 |
Subjects: | Skripsi > Teknika |
Divisions: | Teknika |
Depositing User: | Admin Admin Admin |
Date Deposited: | 29 Jan 2020 10:22 |
Last Modified: | 29 Jan 2020 10:22 |
URI: | http://repository.pip-semarang.ac.id/id/eprint/2043 |
Actions (login required)
View Item |