OPTIMALISASI KERJA PADA AIR CONDITIONER DALAM MENJAGA SUHU RUANG AKOMODASI DI MV. GLOVIS DAYLIGHT

RIZQI, ADITYA PRATAMA (2019) OPTIMALISASI KERJA PADA AIR CONDITIONER DALAM MENJAGA SUHU RUANG AKOMODASI DI MV. GLOVIS DAYLIGHT. Diploma thesis, POLITEKNIK ILMU PELAYARAN SEMARANG.

[img] Pdf (52155845T_SKRIPSI_OPEN_ACCESS)
52155845T_Open_Access.pdf

Download (2MB)
[img] Pdf (52155845T_SKRIPSI_FULLTEXT)
52155845T_Skripsi Full_Text.pdf
Restricted to Repository staff only

Download (3MB) | Request a copy
Official URL: http://www.library.pip-semarang.ac.id

Abstract

ABSTRAKSI Rizqi Aditya Pratama, NIT. 52155845.T, 2019 “Optimalisasi kerja pada Air Conditioner dalam menjaga suhu ruang akomodasi di MV. Glovis Daylight”, skripsi Program Studi Teknika, Program Diploma IV,Politeknik Ilmu Pelayaran Semarang, Pembimbing I: Dwi Prasetyo, M.M, M.Mar. dan Pembimbing II: R.A.J Susilo Hadi W,S.IP.M.M Mesin pendingin adalah suatu rangkaian permesinan bantu yang mampu bekerja untuk menghasilkan suhu atau temperature dingin, ada beberapa komponen utama pada mesin pendingin yaitu Compressor, Condensor, Expansion valve, dan Evaporator yang masing-masing komponen penting tersebut memiliki fungsi dan cara kerja yang berbeda namun saling memengaruhi satu dengan yang lainnya. Mesin pendingin ini sendiri memiliki peranan yang sangat penting yaitu mendinginkan ruangan diatas kapal dan juga memberi rasa nyaman pada crew kapal. Metode yang digunakan dalam penelitian ini adalah metode kualitatif dengan pendekatan metode Fishbone Analysis, menemukan penyebab utama kurang optimalnya kerja Air Conditioner, menemukan dampak kurang optimalnya kerja Air Conditioner serta mengkombinasikannya dengan metode Fault Tree Analysis untuk menemukan upaya dari permasalahan paling mendasar (Basic Event). Hasil yang diperoleh penyebab utama kurang optimalnya kerja Air Conditioner yaitu karena 1) adanya fouling/endapan lumpur pada kondensor 2) kurangnya pengawasan masinis pada Air Conditioner 3) karena adanya kebocoran pada katup dan flange. Hasil penelitian ini menemukan faktor utama yang mengakibatkan kurang optimalnya kerja Air Conditioner yaitu terjadinya fouling/endapan pada pipa-pipa (tube) kondensor sehingga mengganggu proses kondensasi gas freon menjadi cair. Hal tersebut diakibatkan karena kotornya Low Temperature Cooler. Dampak yang terjadi akibat kurang optimalnya kerja Air Conditioner adalah crew merasa kurang nyaman ketika berada disuatu ruangan, timbul kerugian yang cukup besar baik dampak internal yaitu pada mesin maupun dampak eksternal. Kemudian upaya yang dilakukan yaitu melakukan perawatan pada permesinan sesuai dengan Plan Mantenance System. Serta perlu dilakukan secara rutin pengetesan air pada Low Temperature Cooler agar kualitas air tersebut tetap terjaga dan nilai guna suatu permesinan dapat bertahan lebih lama. ABSTRACT Rizqi Aditya Pratama, NIT. 52155845.T, 2019 “Optimization of work on Air Conditioners to maintaining the temperature of the accommodation space in MV. Glovis Daylight”, Technical, Diploma IV, Semarang Merchant Marine Polytechnic, 1st Supervisior: Dwi Prasetyo, M.M, M.Mar.E and 2nd Supervisior: R.A.J Susilo Hadi W,S.IP.M.M The refrigerator machine is a series of auxiliary machining machines capable of working to produce cold temperatures or temperatures, there are several main components in refigerator machines, namely compressors, condensers, expansion valves, and evaporators, each of which has its own components related to work tools and work methods that are mutually connected to influence one another. This refrigerator machine has a very important role, which is to cool the space on the ship and also provide comfort to the crew. The method used in this study is a qualitative method with Fishbone Analysis approach, finding the main causes of the less optimal work of Air Conditioners, finding the effect of the less optimal work of Air Conditioners and combining them with the Fault Tree Analysis method to find efforts from the Basic Event. The results obtained by the main causes of less than optimal working Air Conditioner are because 1) there is fouling / sludge on the condenser 2) lack of engineer supervision on Air Conditioner 3) due to a leak in the valve and flange. The results of this study find the main factors that lead to less optimal work of Air Conditioners, namely the occurrence of fouling / sediment on the pipes (tubes) condensers so that it disrupts the process of condensing freon gas to be liquid. This is due to the dirty Low Temperature Cooler. Impacts that occur due to lack of optimal work Air Conditioner is a crew feel uncomfortable when located in a room, there is considerable loss arising both internal impacts, namely the engine and external impacts. Then the efforts made are doing maintenance on machinery in accordance with the Mantenance System Plan. And it is necessary to routinely test the water in the Low Temperature Cooler so that the water quality is maintained and the use value of a machine can last longer.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Kata Kunci : Mesin Pendingin, Air Conditioner, Metode Fishbone dan Metode Fault Tree Analysis Keywords: Refrigerator, Air Conditioner, Fishbone Method dan Fault Tree Analysis Method.
Subjects: Skripsi > Teknika
Divisions: Teknika
Depositing User: Unnamed user with email perpustakaan@pip-semarang.ac.id
Date Deposited: 05 Mar 2020 12:16
Last Modified: 05 Mar 2020 12:16
URI: http://repository.pip-semarang.ac.id/id/eprint/2019

Actions (login required)

View Item View Item