NUR, WAHID AGUNG WINARNO (2019) TIDAK BEKERJANYA DIESEL GENERATOR YANG MENGAKIBATKAN BLACK OUT DI KAPAL MV. KT 05. Diploma thesis, POLITEKNIK ILMU PELAYARAN SEMARANG.
Pdf (52155779T_SKRIPSI_OPEN_ACCESS)
52155779 T_open_access.pdf Download (2MB) |
|
Pdf (52155779T_SKRIPSI_FULLTEXT)
52155779 T_skripsi_fulltext.pdf Restricted to Repository staff only Download (5MB) | Request a copy |
Abstract
ABSTRAKSI Nur Wahid Agung Winarno, 2019, NIT: 52155779 T, “Tidak bekerjanya diesel generator yang mengakibatkan black out di kapal MV. KT 05”, skripsi Program Studi Teknika, Program Diploma IV, Politeknik Ilmu Pelayaran Semarang, Pembimbing I: H.Rahyono,SP.1. M.M, M.Mar.E, Pembimbing II: Capt. Eko Murdiyanto, M. Pd,M.Mar Auxiliary Engine Diesel Generator adalah suatu permesinan bantu yang berfungsi untuk menghasilkan daya listrik guna memenuhi kebutuhan listrik kapal. Tujuan dari skripsi ini adalah menganalisa faktor menurunya kinerja diesel generator yang mengakibatkan black out, upaya yang dilakukan untuk mengoptimalkan kinerja diesel generator. Metode penelitian yang penulis gunakan adalah metode fishbone analysis dan fault tree analysis, dimana fishbone analysis digunakan untuk menganalisa dari permasalahan, sedangkan fault tree analysis digunakan untuk pembahasan dan menentukan upaya permasalahan. Hasil yang diperoleh dari penelitian ini menunjukan bahwa penyebab menurunya kinerja diesel generator adalah pengabutan injector tidak optimal, kotornya filter bahan bakar, tidak dilaksanakannya standard operational procedure (SOP). Cara mengoptimalkan permasalahan di atas adalah melakukan perawatan secara periodik/berkala terhadap diesel generator betul-betul dijaga terutama pada system bahan bakar agar bisa mengabutkan bahan bakar secara sempurna, dan juga perlu pergantian spare part yang sudah tidak dapat digunakan lagi, dan juga mengecek tekanan bahan bakar dari injector. ABSTRACT Nur Wahid Agung Winarno, 2019, NIT: 52155779 T,“The unworking of diesel generator that caused black out on MV. KT 05”, Thesis of Engineering Study Program, Diploma IV Program, Merchant Marine Polytechnic of Semarang, Advisor I: H.Rahyono,SP.1. M.M, M.Mar.E, Advisor II: Capt. Eko Murdiyanto, M. Pd,M.Mar Auxiliary Engine Diesel Generator is a auxiliary machinery that functions to produce electrical power to meet the electricity needs of the ship. The purpose of this thesis is to analyze the declining factor in the performance of diesel generators that result in blackout, efforts made to optimize the performance of diesel generators. The research method that I use is the method of fishbone analysis and fault tree analysis, where fishbone analysis is used to analyze problems, while fault tree analysis is used to discuss and determine the problem effort. The results obtained from this study indicate that the cause of the declining performance of diesel generators is that the injectors are not optimal, dirty fuel filters, no standard operational procedure (SOP). To optimize the problems is to maintain the diesel generators periodically, especially in fuel systems so that they can completely fuel the fuel. Furthermore, the spare part that are no longer usable must be replaced with the new one, and also check the pressure of the fuel in the injectors.
Item Type: | Thesis (Diploma) |
---|---|
Uncontrolled Keywords: | Kata Kunci: diesel generator, black out, injector, fishbone, fault tree analysis Keywords: diesel generator, black out, injector, fishbone, fault tree analysis |
Subjects: | Skripsi > Teknika |
Divisions: | Teknika |
Depositing User: | Admin Admin Admin |
Date Deposited: | 27 Jul 2020 00:45 |
Last Modified: | 27 Jul 2020 00:45 |
URI: | http://repository.pip-semarang.ac.id/id/eprint/1968 |
Actions (login required)
View Item |