ANALISIS PENYEBAB TERJADINYA KEBOCORAN PADA ECONOMIZER SIDE DI COMPOSITE BOILER TYPE MV. PAN GLOBAL

ARIF, BUDI U (2019) ANALISIS PENYEBAB TERJADINYA KEBOCORAN PADA ECONOMIZER SIDE DI COMPOSITE BOILER TYPE MV. PAN GLOBAL. Diploma thesis, POLITEKNIK ILMU PELAYARAN SEMARANG.

[img] Pdf (52155704T_SKRIPSI_OPEN_ACCESS)
52155704T_ Open_Access.pdf

Download (2MB)
[img] Pdf (52155704T_SKRIPSI_FULLTEXT)
52155704T_Skripsi_Fulltext_.pdf
Restricted to Repository staff only

Download (3MB) | Request a copy
Official URL: http://www.library.pip-semarang.ac.id

Abstract

ABSTRAKSI Arif Budi Utama, 2019, NIT : 52155704.T, “Analisis Penyebab Terjadinya Kebocoran Pada Economizer Side di Composite Boiler Type Mv. Pan Global”, skripsi Program Studi Teknika, Progran Diploma IV, Politeknik Ilmu Pelayaran Semarang, Pembimbing I: Abdi Seno, M.Si., M.Mar.E. dan Pembimbing II: Yustina Sapan S.ST., M.M. Economizer di composite boiler adalah suatu pesawat bantu diatas kapal yang berfungsi untuk memproduksi uap panas dengan tekanan lebih dari 1 bar atau 1 atmosfir yang digunakan untuk media pemanas bahan bakar, minyak lumas dan akomodasi lainnya di atas kapal. Economizer memanfaatkan panas dari gas buang mesin induk dalam proses produksi uap untuk menghemat penggunaan bahan bakar. Kebocoran pada economizer side di composite boiler menyebabkan gangguan pada proses produksi uap di atas kapal. Jenis metode penelitian yang penulis gunakan dalam penyusunan skripsi ini adalah deskriptif kualitaf dengan menggunakan pendekatan fault tree analysis (FTA) untuk mempermudah dalam teknik analisis data. Penulis juga menggunakan metode pengumpulan data yang penulis lakukan adalah dengan cara observasi, dokumentasi dan wawancara untuk memperkuat dalam analisis data. Tujuan dari penelitian ini adalah untuk mengetahui faktor penyebab kebocoran pada economizer side di composite boiler type, dampak dari faktor penyebab kebocoran pada economizer side di composite boiler type dan upaya yang dilakukan untuk mencegah faktor penyebab kebocoran pada economizer side di composite boiler type Mv. Pan Global. Berdasarkan hasil penelitian penulis, dapat disimpulkan bahwa faktor penyebab kebocoran pada economizer side di composite boiler type MV. Pan Global adalah, 1) Kandungan air economizer boiler kurang sesuai yang dapat disebabkan oleh kondisi air keruh/kotor, tingginya kandungan chloride/klorida dan rendahnya nilai pH. 2) Lamanya usia pipa economizer boiler. 3) Tekanan uap berlebih pada economizer boiler. Dampak yang ditimbulkan adalah 1) Endapan kotoran pada economizer boiler, kerak/scale pada economizer tube dan korosi pada economizer boiler. 2) Melemahnya konstruksi economizer boiler. 3) Pressure stress pada economizer boiler. Untuk mencegah faktor-faktor penyebab kebocoran economizer upaya yang harus dilakukan adalah dengan, 1) Penggantian cascade filter. 2) Pemberian BWT (Boiler Water Treatment). 3) Chemical treatment dan rutin melakukan blowdown. ABSTRACT Arif Budi Utama, 2019, NIT: 52155704.T, "Analysis the Causes of Leakage at Economizer Side at Composite Boiler Type MV. Pan Global", Thesis Study Program, Diploma IV Program, Semarang Shipping Science Polytechnic, Advisor I: Abdi Seno, M.Sc., M.Mar.E. and Advisor II: Yustina Sapan S.ST., M.M. Economizer in a composite boiler is an auxiliary engine on a ship that functions to produce high temperature steam with a pressure of more than 1 bar or 1 atmosphere that is used for fuel heating media, lubricating oil and other accommodations on board. Economizer utilizes heat from the main engine exhaust gas in the steam production process to save fuel use. The economizer side leak in the composite boiler caused a disruption in the steam production process on the ship. The type of research method that the author uses in the preparation of this thesis is descriptive qualitative using a fault tree analysis (FTA) approach to simplify data analysis techniques. The author also uses data collection methods that the author does is by way of observation, documentation and interviews to strengthen the data analysis. The purpose of this study was to find out the causes of leakage on the economizer side in the composite boiler type, the impact of the leakage factors on the economizer side on the composite boiler type and efforts were made to prevent the leakage factor on the economizer side in the composite boiler type Mv. Pan Global. Based on the results of the author's research, it can be concluded that the leakage factor in the economizer side in the composite boiler type MV. Pan Global is, 1) The water content of the boiler economizer is not suitable which can be caused by turbid / dirty water conditions, high content of chloride and low pH value. 2) The age of the pipe economizer boiler. 3) Excess steam pressure on the boiler economizer. The impact is 1) Dirt deposits on the boiler economizer, scale on the economizer tube and corrosion on the boiler economizer. 2) Weakening the construction of the economizer boiler. 3) Pressure stress on the boiler economizer. To prevent the economic factors causing leakage efforts to be done is, 1) Replace the cascade filter. 2) Give BWT (Boiler Water Treatment). 3) Chemical treatment and routinely blow down.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Kata kunci : Economizer side, composite boiler, kebocoran, FTA. Keywords: Economizer side, composite boiler, leakage, FTA
Subjects: Skripsi > Teknika
Divisions: Teknika
Depositing User: Admin Admin Admin
Date Deposited: 10 Jul 2020 02:06
Last Modified: 10 Jul 2020 02:06
URI: http://repository.pip-semarang.ac.id/id/eprint/1868

Actions (login required)

View Item View Item