ABSTRAKSI Ardi Danu Tirta, 2019, NIT : 51145429.T, “Analisis berkurangnya produksi air tawar pada fresh water generator di MV. Lumoso Permai”, skripsi Program Studi Teknika, Program Diploma IV, Politeknik Ilmu Pelayaran Semarang, Pembimbing I: Agus Hendro Waskito, MM Pembimbing II: Febria Sujarman, MT. Fresh Water Generator adalah suatu sistem yang berfungsi untuk memproses air laut menjadi air tawar melalui tahapan penguapan dan kondensasi. Tersedianya air tawar merupakan hal yang mutlak bagi kelancaran operasional kapal misalnya untuk pendingin mesin induk, pendingin mesin bantu, pengisi air ketel uap, dan lain-lain. Masalah yang terjadi pada MV. Lumoso Permai adalah berkurangnya produksi air tawar untuk menangani masalah tersebut dilakukan pengecekan dan perawatan yang benar. Penelitian bertujuan untuk mengetahui apa saja penyebab menurunnya produksi air tawar pada fresh water generator, Untuk mengetahui dampak apa saja dari penyebab berkurangnya produksi air tawar pada fresh water generator, dan untuk mengetahui cara mangatasi penyebab dari turunnya produksi air tawar pada fresh water generator. Metode penelitian yang penulis gunakan dalam penyusunan skripsi ini adalah metode studi kasus, SHEL dan USG (Urgency, Seriously, Growth) yang menghasilkan data deskriftif berupa kata-kata tertulis dari orang-orang dan perilaku yang diamati. Dalam mengumpulkan data berupa pendekatan terhadap obyek melalui observasi, wawancara secara langsung terhadap subyek serta menggunakan dokumen dan data-data yang berhubungan dengan.Teknik pengumpulan data dilakukan melalui observasi, dokumentasi dan studi kepustakaan secara langsung terhadap subyek yang berhubungan dengan fresh water generator. Dapat disimpulkan bahwa faktor penyebab menurunnya produksi air tawar pada fresh water generator adalah sistem kontrol yang digunakan untuk mengatur temperatur distilling plant tidak sesuai dengan manual book, adanya kerusakan rubber seal, air laut kotor, perawatan terhadap fresh water generator type JWSP-26-C80 tidak sesuai manual book. Dampak yang diakibatkan oleh faktor yang menyebabkan timbulnya scale pada feed water side evaporator adalah produksi air tawar pada fresh water generator akan menurun dikarenakan supply untuk pemanas kurang, dapat menurunkan kevakuman pada fresh water generator dan mengakibatkan tidak maksimalnya kinerja fresh water generator, penumpukan kotoran pada seachest dan tekanan air laut pada pompa akan turun, pembentukan scale pada feed water side evaporator. Upaya yang dilakukan untuk mengatasi faktor penyebab timbulnya scale pada feed water side evaporator adalah dilakukan pengecekan dan me-reset atur ulang sistem alarm, dilakukan pengecekan dan melakukan penggantian rubber seal yang telah rusak, tidak mengoperasikan fresh water generator di wilayah air laut yang kotor dan membersihkan sea chest secara rutin. melakukan descaling pada fresh water generator sesuai maintenance plan dan melakukan pembersihan physical dengan benar. ABSTRACT Ardi Danu Tirta, 2019, NIT : 51145429.T, “Analysis Decreasing of Fresh Water Production in Fresh Water Generator on MV. Lumoso Permai”, Program Diploma IV, Technical, Merchant Marine Polytechnic of Semarang, Supervising I: Agus Hendro Waskito, MM and Supervising II: Febria Sujarman, MT. Fresh Water Generator is a system that functions to process sea water into fresh water through the stages of evaporation and condensation. The availability of fresh water is an absolute thing for the smooth operation of the ship for example main engine coolant, auxiliary engine coolant, boiler water filler, etc. The problem at MV. Lumoso Permai is decrease of fresh water production, for resolve that problem, must checking and maintenance with connect. The research have purpose to find out what are the causes of decrease production of fresh water in fresh water generator, to find out what is the impact from decrease production of fresh water in fresh water generator and to find out, how to resolve from decrease production of fresh water in fresh water generator. The research method that I use in the preparation of this thesis is a case study method, SHEL analysis and Urgency, Seriously, Growth Analysis which produces descriptive data in the form of written words from people and observed behavior. In collecting data in the form of approaches to objects through observation, interviews directly with the subject and using documents and data relating to. Data collection techniques are carried out through observation, documentation and literature studies directly on subjects related to fresh water generators. From the results of the research and discussion of the problem it was found that the decrease in the production of fresh water on the fresh water generator is control system which used for manage temperature distilling plant is not suitable with manual book. The damage of rubber seal, dirty sea water, maintenance of fresh water generator type JWSP-26-C80 is not suitable with manual book. The impact from factor that cause scale on feed water evaporator side is production of fresh water on fresh water generator will be decrease because supply for heater is minus, can reduce vacuum in fresh water generator and make fresh water generator can not work with optimal, sewage will be increase on sea chest and pressure of sea water in pump will be down, the scale will be formed in feed water evaporator side. To resolve the scale on feed water evaporator side is with checking and reset the alarm system, checking and change the broken rubber seal, do not operate fresh water generator in dirty sea water zone and clean sea chest with routine, do descaling on fresh water generator suitable with maintenance plan and cleaning phsycal with correct.
Item Type: | Thesis (Diploma) |
---|---|
Uncontrolled Keywords: | Kata kunci: Fresh Water Generator, Kerak Evaporator, Tekanan Pompa Ejector. Keywords: Fresh Water Generator, Crust Evaporator, Pressure Ejector Pump. |
Subjects: | Skripsi > Teknika |
Divisions: | Teknika |
Depositing User: | Admin Admin Admin |
Date Deposited: | 04 Oct 2019 07:49 |
Last Modified: | 04 Oct 2019 07:49 |
URI: | http://repository.pip-semarang.ac.id/id/eprint/1706 |
Actions (login required)
View Item |