Analisa tingginya temperatur fresh water cooler pada engine diesel generator di MT. Sindang

Tri, Wahyudi (2018) Analisa tingginya temperatur fresh water cooler pada engine diesel generator di MT. Sindang. Diploma thesis, POLITEKNIK ILMU PELAYARAN SEMARANG.

[img]
Preview
Text (DAFTAR RIWAYAT HIDUP)
DAFTAR RIWAYAT HIDUP.PDF

Download (4MB) | Preview
[img]
Preview
Text (HALAMAN PERNYATAAN)
HALAMAN PERNYATAAN.PDF

Download (4MB) | Preview
[img]
Preview
Text (HALAMAN PERSETUJUAN)
HALAMAN PERSETUJUAN.PDF

Download (4MB) | Preview
[img]
Preview
Text (HALAMAN PENGESAHAN)
HALAMAN PENGESAHAN.PDF

Download (4MB) | Preview
[img]
Preview
Text (TW)
TW.PDF

Download (4MB) | Preview
[img]
Preview
Text (KUISIONER ANALISI SWOT)
KUISIONER ANALISIS SWOT.PDF

Download (4MB) | Preview
[img]
Preview
Text (5. HALAMAN MOTO)
5. HALAMAN MOTTO FIX.PDF

Download (4MB) | Preview
[img]
Preview
Text (7. KATA PENGANTAR)
7. KATA PENGANTAR FIX.PDF

Download (4MB) | Preview
[img]
Preview
Text (8. DAFTAR ISI)
8. DAFTAR ISI.PDF

Download (4MB) | Preview
[img]
Preview
Text (9. DAFTAR GAMBAR)
9. DAFTAR GAMBAR.PDF

Download (4MB) | Preview
[img]
Preview
Text (6. HALAMAN PERSEMBAHAN)
6. HALAMAN PERSEMBAHAN FIX.PDF

Download (4MB) | Preview
[img]
Preview
Text (8.1 DAFTAR TABEL)
8.1 DAFTAR TABEL.PDF

Download (4MB) | Preview
[img]
Preview
Text (WAWANCARA)
WAWANCARA.PDF

Download (4MB) | Preview
[img]
Preview
Text (10. DAFTAR LAMPIRAN (2))
10. DAFTAR LAMPIRAN (2).PDF

Download (4MB) | Preview
[img]
Preview
Text (BAB I)
BAB I FIXXX.PDF

Download (4MB) | Preview
[img]
Preview
Text (ABSTRAK)
ABSTRAKSI N ABSTRACT FIX.PDF

Download (4MB) | Preview
[img]
Preview
Text (BAB II)
BAB II.PDF

Download (4MB) | Preview
[img] Text (BAB III)
BAB III.PDF
Restricted to Registered users only

Download (4MB) | Request a copy
[img] Text (BAB IV)
BAB IV FIX BGTMMMMMMM.PDF
Restricted to Registered users only

Download (4MB) | Request a copy
[img]
Preview
Text (CREW LIST)
CREW LIST.PDF

Download (4MB) | Preview
[img]
Preview
Text (DAFTAR PUSTAKA)
DAFTAR PUSTAKA.PDF

Download (4MB) | Preview
Official URL: http://www.library.pip-semarang.ac.id

Abstract

Tri Wahyudi, 2018, NIT: 50135036.T, “Analisa tingginya temperatur fresh water cooler pada engine diesel generator di MT. Sindang”, penelitian Program Studi Teknika, Program Diploma IV, Politeknik Ilmu Pelayaran Semarang, pembimbing I: Achmad Wahyudiono, M.M., M.Mar.E., Pembimbing II: Capt.Firdaus Sitepu, S.ST, M.Si, M.Mar Genset is an abbreviation of the word generator set which means a combination of two devices ie engine (player) and generator or alternator (electric generator). The principle of work law generator faraday ie when a conductor is rotated in a magnetic field to cut the magnetic force line (GGM), it will cause the electric force (GGL) in units of volts at the end of the delivery, the electric current on the ship MT.Sindang using alternating current behind (AC). If there is damage to the components in the diesel engine generator will greatly disrupt the performance of diesel generator engine because the machine serves as a source of electricity on board. Diesel engine generator failure in MT. Sindang is a generator number 1 high freshwater cooler temperature at that time is 80 ° C while the normal temperature is 60-70 ° C so that there is damage to the diesel generator components and disrupt the operational activities of the ship. The purpose of this research is to find out what the main factors that cause the high temperature fresh water cooler on diesel generator engine in MT. Sindang, to know the main impact of what happened from the high temperature fresh water cooler on diesel generator engine in MT. Sindang, and what efforts should be done to prevent high temperature fresh water cooler on diesel generator engine in MT. Sindang This study uses data analysis techniques Strengths, Weaknesses, Opportunities, and Threats (SWOT) is the systematic identification of various factors to formulate problem solving strategies. Data collection techniques using questionnaire, interview, observation, documentation and literature study. The results of this study indicate that the main factor that causes the high temperature fresh water cooler to 80 ° C on diesel generator engine in MT. Sindang is a blockage of heat exchanger by the dirt from the sea and the end of zinc anode. The main impact that occurs due to high temperature fresh water cooler on diesel generator engine in MT. Sindang is the breaking of the cylinder liner and the breaking of the connecting rod on the diesel generator engine, the decrease in the engine power of the diesel generator, and the breakdown of other components. And how to anticipate the damage of connecting rod on diesel generator engine in MT. Sindang is a good management of maintenance and repair of diesel generator engines, and the availability of spare parts on board. Keywords: fresh water cooler, diesel generator engine

Item Type: Thesis (Diploma)
Uncontrolled Keywords: fresh water cooler, diesel generator engine
Subjects: Skripsi > Teknika
Divisions: Teknika
Depositing User: mahasiswa taruna mahasiswa
Date Deposited: 30 Jan 2019 05:38
Last Modified: 30 Jan 2019 05:38
URI: http://repository.pip-semarang.ac.id/id/eprint/590

Actions (login required)

View Item View Item