SIYAM, RIVALDI (2018) IDENTIFIKASI NAIKNYA SUHU PENDINGIN AIR TAWAR PADA MESIN INDUK DI MV. SINAR BALI. Diploma thesis, POLITEKNIK ILMU PELAYARAN SEMARANG.
|
Text (BAB I)
BAB I.pdf Download (304kB) | Preview |
|
Text (BAB III)
BAB III.pdf Restricted to Registered users only Download (628kB) | Request a copy |
||
|
Text (BAB V)
BAB V.pdf Download (332kB) | Preview |
|
|
Text (ABSTRACT)
13. ABSTRACT xv.pdf Download (280kB) | Preview |
|
|
Text (DAFTAR PUSTAKA)
DAFTAR PUSTAKA.pdf Download (429kB) | Preview |
|
Text (BAB IV)
BAB IV.pdf Restricted to Registered users only Download (980kB) | Request a copy |
||
|
Text (LAMPIRAN HASIL WAWANCARA)
LAMPIRAN HASIL WAWANCARA.pdf Download (305kB) | Preview |
|
|
Text (LAMPIRAN FOTO)
LAMPIRAN FOTO.pdf Download (428kB) | Preview |
|
|
Text (SAMPUL DEPAN)
1. SAMPUL DEPAN.pdf Download (229kB) | Preview |
|
|
Text (HALAMAN PENGESAHAN)
3. HALAMAN PENGESAHAN.pdf Download (769kB) | Preview |
|
|
Text (HALAMAN PERSETUJUAN)
2. HALAMAN PERSETUJUAN.pdf Download (775kB) | Preview |
|
|
Text (HALAMAN PERNYATAAN)
4. HALAMAN PERNYATAAN..pdf Download (652kB) | Preview |
|
|
Text (HALAMAN PERSEMBAHAN)
6. HALAMAN PERSEMBAHAN vi.pdf Download (184kB) | Preview |
|
|
Text (HALAMAN MOTTO)
5. HALAMAN MOTTO v.pdf Download (282kB) | Preview |
|
|
Text (KATA PENGANTAR)
7. KATA PENGANTAR vii-viii.pdf Download (390kB) | Preview |
|
|
Text (DAFTAR ISI)
8. DAFTAR ISI ix-x.pdf Download (193kB) | Preview |
|
|
Text (DAFTAR TABEL)
9. DAFTAR TABEL xi.pdf Download (183kB) | Preview |
|
|
Text (DAFTAR GAMBAR)
10. DAFTAR GAMBAR xii.pdf Download (186kB) | Preview |
|
|
Text (DAFTAR LAMPIRAN)
11. DAFTAR LAMPIRAN xiii.pdf Download (181kB) | Preview |
|
|
Text (ABSTRAK)
12. ABSTRAKSI xiv.pdf Download (292kB) | Preview |
|
|
Text (DAFTAR RIWAYAT HIDUP)
DAFTAR RIWAYAT HIDUP.pdf Download (197kB) | Preview |
|
|
Text (BAB II)
BAB II.pdf Download (671kB) | Preview |
Abstract
Siyam Rivaldi, 51145390.T, 2018 ,”Identification of rising temperature of fresh water cooling on MV. Sinar Bali”, Technical Department, Diploma IV Program, Merchant Marine Polytechnic of Semarang, Material Adviser (I): H. Mustholiq, MM and as Methodologi and Writing Adviser (II): Sri Purwantini, SE, S.Pd, MM. Main Engine is the main component that has a very important role on board to support the operation of the ship so that the ship can sail activities well. Performance of main engine powered by multiple systems one of which is the fresh water cooling system. MV. Sinar Bali never experienced a problem with the cooling of main engine cooling water as high temperature. This is a descriptive qualitative research with data analysis technique fishbone analysis and fault tree analysis. In determining the problem factors use Fishbone Anaylis technique using for to know the cause-effect of the factors and Fault Tree Analysis technique using for to find solve of the problems. Result of research conducted on fresh water cooling system of main engine showed that the cause of the temperature rising is fresh water cooling cooler dirty, pipeline of the fresh water cooling system leaking, and cylinder jacket cooling clogged by rubber seal, so it was undertaken efforts to fix the problems. Efforts are made is by doing the Standart Operating Procedure (SOP) well, cleaning the cooler, maintenance of fresh water cooling pipelines and overhaul cylinder jacket cooling to remove rubber seal from cylinder jacket cooling. Keyword: Main Engine, Fresh Water Cooling System, Fishbone and Fault Tree Analysis
Item Type: | Thesis (Diploma) |
---|---|
Uncontrolled Keywords: | Main Engine, Fresh Water Cooling System, Fishbone and Fault Tree Analysis |