ANALISA PENGARUH PERUBAHAN SUHU AIR LAUT TERHADAP KINERJA CENTRAL COOLER PADA MV SAN PEDRO BRIDGE

ARYANDA, GALANG PRADANA (2018) ANALISA PENGARUH PERUBAHAN SUHU AIR LAUT TERHADAP KINERJA CENTRAL COOLER PADA MV SAN PEDRO BRIDGE. Diploma thesis, POLITEKNIK ILMU PELAYARAN SEMARANG.

[img] Text (14 BA B 1 FIX)
14-bab 1 FIX (1).pdf

Download (1MB)
[img] Text (15 BAB 2 FIX)
15-bab 2 FIX (10).pdf

Download (1MB)
[img] Text (16 BAB 3 FIX)
16-Bab 3 FIX (22).pdf
Restricted to Registered users only

Download (1MB) | Request a copy
[img] Text (17-BAB 4 FIX)
17-BAB 4 FIX (32).pdf
Restricted to Registered users only

Download (1MB) | Request a copy
[img] Text (18-BAB 5 FIX)
18-bab 5 FIX (59).pdf

Download (1MB)
[img] Text (19-DAFTAR PUSTAKA)
19-DAFTAR PUSTAKA (61).pdf

Download (0B)
[img] Text (21-LAMPIRAN 2 CREW LIST)
21-Lampiran 2 crew list (65).pdf

Download (0B)
[img] Text (22-LAMPIRAN 3 PELABUHAN)
22-Lampiran 3 pelabuhan (66).pdf

Download (0B)
[img] Text (20-LAMPIRAN 1 SHIPS PARTICULAR)
20-Lampiran 1 SHIPS PARTICULAR (63).pdf

Download (0B)
[img] Text (23-LAMPIRAN 4 PIPING DIAGRAM)
23-Lampiran 4 PIPING DIAGRAM (67).pdf

Download (0B)
[img] Text (24-LAMPIRAN 5 CONTOH KUISIONER)
24-Lampiran 5 contoh kuisioner (68).pdf

Download (0B)
[img] Text (25-LAMPIRAN 6 HASIL KUISIONER)
25-Lampiran 6 hasil kuisioner (70).pdf

Download (0B)
[img] Text (0- COVER DEPAN)
0-COVER DEPAN.pdf

Download (0B)
[img] Text (1-HALAMAN JUDUL)
1-HALAMAN JUDUL.pdf

Download (0B)
[img] Text (26-DAFTAR RIWAYAT HIDUP)
26-DAFTAR RIWAYAT HIDUP (71).pdf

Download (0B)
[img] Text (2-HALAMAN PERSETUJUAN)
2-HALAMAN PERSETUJUAN (ii).pdf

Download (0B)
[img] Text (3-HALAMAN PENGESAHAN)
3-HALAMAN PENGESAHAN(iii).pdf

Download (0B)
[img] Text (4-HALAMAN PERNYATAAN)
4-HALAMAN PERNYATAAN (iv).pdf

Download (0B)
[img] Text (5-MOTTO)
5-MOTTO (v).pdf

Download (0B)
[img] Text (6-HALAMAN PERSEMBAHAN)
6-HALAMAN PERSEMBAHAN (vi).pdf

Download (0B)
[img] Text (7-KATA PENGANTAR)
7- KATA PENGANTAR (vii).pdf

Download (0B)
[img] Text (8-DAFTAR ISI)
8-DAFTAR ISI (ix).pdf

Download (0B)
[img] Text (9-DAFTAR GAMBAR)
9-DAFTAR GAMBAR (xi).pdf

Download (0B)
[img] Text (DAFTAR TABEL)
10-DAFTAR TABEL (xii).pdf

Download (0B)
[img] Text (11-DAFTAR LAMPIRAN)
11-Daftar Lampiran (xiii).pdf

Download (0B)
[img] Text (12-ABSTRAKSI)
12-ABSTRAKSI (xiv).pdf

Download (0B)
[img] Text (13-ABSTRACK)
13-ABSTRACT (xv).pdf

Download (0B)
Official URL: htttp://www.library.pip-semarang.ac.id

Abstract

Aryanda Galang Pradana, 2017, NIT: 501345019.T, “Analysis on temperature change to central cooler performance at MV San Pedro Bridge”, Thesis of Marine Engineering Department, Diploma IV Programme, Politeknik Ilmu Pelayaran Semarang, 1st Supervisor: H. Amad Narto, M.Pd, M.Mar.E, 2nd Supervisor: Andy Wahyu Hermanto, S.T, M.T. Central fresh water cooler is principal machinery consist of pipes where fresh waters which are used to cool down machineries on board is being cooled. Providing fresh waters with right temperature according machineries needing are crucial, in which it can boost the machineries operational quality, so that the machineries performance is as expected. Thus, the outcome from the central cooler will optimize the cooling system. Temperature diffence from the needed temperature will decrease the cooling performance. Method which is used in this thesis are qualitative descriptive method. Additionally, the writer used SWOT method as data anaysis technique to investigate problems which are occur at the central cooler, namely the factors causing the decreased performance of the central cooler and efforts to be taken to overcome those factors. Then, those factors are systematically analyzed by considering the strengths, weakness, opportunities, and threats obtained from the environment on board in order to formulate the strategies to be taken. As the research that had been done by the writer on MV. San Pedro Bridge from 03rd February 2016 until 07th December 2016, we can conclude that the decreased of the central cooler performance is caused by more load at sea water pump because sea water temperature was too low. Furthermore, environment temperature was low, causing temperature stress at ship’s elements and leading to gasket or even pipe leakage. To overcome these problems, manual adjustment at sea water system and upgrading gasket and always ready for the leaks can be done to prevent the worst scenario from happening. Kata kunci: central cooler, sea water, SWOT.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: central cooler, sea water, SWOT.
Subjects: Skripsi
Skripsi > Teknika
Divisions: Teknika
Depositing User: Mr Agus Wahyudi
Date Deposited: 30 Jan 2019 06:46
Last Modified: 06 Feb 2019 02:47
URI: http://repository.pip-semarang.ac.id/id/eprint/583

Actions (login required)

View Item View Item