OPTIMALISASI KINERJA BOSCH PUMP PADA MOTOR DISEL PENGGERAK GENERATOR DI KAPAL MV. ENERGY MIDAS

ANDIKA, PRATAMA (2020) OPTIMALISASI KINERJA BOSCH PUMP PADA MOTOR DISEL PENGGERAK GENERATOR DI KAPAL MV. ENERGY MIDAS. Diploma thesis, POLITEKNIK ILMU PELAYARAN SEMARANG.

[img] Pdf (52155796T_SKRIPSI_FULLTEXT)
52155796T_SKRIPSI_FULLTEXT.pdf
Restricted to Repository staff only

Download (4MB) | Request a copy
[img] Pdf (52155796T_SKRIPSI_OPEN_ACCESS)
52155796T_SKRIPSI_OPEN_ACCESS.pdf

Download (3MB)
Official URL: http://www.library.pip-semarang.ac.id

Abstract

INTISARI Andika Pratama, 2020, NIT: 52155796 T, “Optimalisasi Kinerja Bosch Pump Pada Motor Diesel Penggerak Generator Di Kapal Mv. Energy Midas”, skripsi Program Studi Teknika, Program Diploma IV, Politeknik Ilmu Pelayaran Semarang, Pembimbing I: Abdi Seno, M.Si, Pembimbing II: Dr. Winarno, S.ST., M.H. Penelitian ini dilatar belakangi oleh terjadinya penurunan tekanan Bosch Pump pada motor diesel penggerak generator, Bosch Pump adalah bagian yang paling penting dari mesin disel yang berfungsi untuk menyalurkan bahan bakar ke Nozzle Injector, menentukan jumlah bahan bakar yang di injeksikan serta menentukan timing injeksi nya, injeksi bahan bakar di lakukan dengan bantuan cam dan camchaft, untuk alasan ini ada kebutuhan dari sistem pasokan bahan bakar di ukur dan memonitor bahan bakar kedalam rung bakar. Jenis metode penelitian yang penulis gunakan dalam penyusunan skripsi ini adalah deskriptif kualitaf dengan menggunakan pendekatan SHEL untuk mempermudah dalam teknik analisis data. Metode pengumpulan data yang penulis lakukan adalah dengan cara observasi, wawancara dan studi dokumentasi untuk memperkuat dalam analisis data. Tujuan dalam penelitian ini adalah untuk mengetahui penyebab tidak optimalnya kerja bosch pump, dampak yang ditimbulkan dari tidak optimalnya bosch pump motor diesel generator, dan upaya cara mengoptimalkan kerja bosch pump motor diesel generator di MV. Energy Midas. Kesimpulan dari penelitian ini adalah faktor- faktor yang menyebabkan tidak optimalnya kerja bosch pump motor diesel generator adalah disebabkan oleh kurang telitinya saat pengecekan dan perawatan, gangguan yang terjadi meliputi lecetnya plunger bosch pump dan bahan bakar kotor. Kedua, dampak yang di timbulkan karena gangguan pada Bosch pump mengakibatkan jumlah bahan bakar tidak dapat semuanya di tekan ke injektor karena bahan bakar lolos melewati celah goresan plunger dan akan terjadi kekosongan bahan bakar pada pipa tekan. Ketiga, upaya yang dilakukan untuk menanggulangi tidak optimalnya kerja bosch pump motor diesel generator adalah perawatan dan perbaikan terhadap bosch pump sesuai jadwal, penyediaan suku cadang sesuai kebutuhan dari perawatan dan kerusakan, serta ke mengembalikan pengaturan. Saran dari penelitian ini adalah melakukan perawatan berkala secara rutin, pemahaman terhadap pengoperasian bosch pump motor diesel generator secara baik. ABSTRACT Andika Pratama, 2020, NIT: 52155796 T, “Optimization of Bosch Pump Diesel generator motor on MV. Energy Midas”, thesis of Technical Department, Diploma IV Program, Semarang Merchant Marine Polytechnic, Supervisor I: Abdi Seno, M.Si, Supervisor II: Dr. Winarno, S.ST., M.H. This research is motivated by the occurrence of Bosch Pump pressure drop on the generator motor diesel engine, Bosch Pump is the most important part of the diesel engine that serves to deliver fuel to the Nozzle Injector, determine the amount of fuel injected and determine the injection timing, injection fuel is done with the help of cam and camchaft, for this reason there is a need for the fuel supply system to be measured and monitored fuel into the fuel chamber. The type of research method that the author uses in the preparation of this thesis is descriptive quality using the SHEL approach to facilitate data analysis techniques. The method of data collection by the author is by observation, interview and documentation study to strengthen the data analysis. The purpose of this study was to determine the cause of the non-optimal operation of the bosch pump, the impact caused by the non-optimal bosch pump diesel generator motor, and efforts to optimize the work of the diesel generator motor bosch pump in MV. Energy Mida The conclusion of this research is the factors that cause the optimum work of the diesel generator motor bosch pump is caused by lack of precision when checking and maintenance, disruptions that occur include the blister bosch pump plunger and dirty fuel. Second, the impact caused by disruption in the Bosch pump causes the amount of fuel can not all be pressed into the injector because the fuel passes through the plunger scratches and there will be a void of fuel in the pressure pipe. Third, the efforts made to overcome the work of the bosch pump diesel generator motor are not optimal are the maintenance and repair of the Bosch pump on schedule, the supply of spare parts according to the needs of maintenance and damage, and to restore the settings. Suggestion from this research is to do regular maintenance on a regular basis, an understanding of the operation of the diesel generator motor bosch pump properly

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Kata kunci: Optimalisasi, Motor diesel generator, bosch pump. Keywords: Optimization, diesel generator motor, bosch pump.
Subjects: Skripsi > Teknika
Divisions: Teknika
Depositing User: Unnamed user with email perpustakaan@pip-semarang.ac.id
Date Deposited: 23 Sep 2020 00:42
Last Modified: 23 Sep 2020 00:42
URI: http://repository.pip-semarang.ac.id/id/eprint/2573