PENGARUH SUHU TINGGI TERHADAP SIRKULASI ZAT PENDINGIN SISTEM AIR CONDITIONER DI MT. SEPINGGAN

NARENDRA, ARRIDHO PRADANA (2018) PENGARUH SUHU TINGGI TERHADAP SIRKULASI ZAT PENDINGIN SISTEM AIR CONDITIONER DI MT. SEPINGGAN. Diploma thesis, POLITEKNIK ILMU PELAYARAN SEMARANG.

[img]
Preview
Text (COVER)
1. SAMPUL.PDF

Download (190kB) | Preview
[img]
Preview
Text (COVER)
2. HALAMAN JUDUL.PDF

Download (190kB) | Preview
[img]
Preview
Text (HALAMAN PENGESAHAN)
4. HALAMAN PENGESAHAN.PDF

Download (187kB) | Preview
[img]
Preview
Text (HALAMAN PERSEMBAHAN)
7. HALAMAN PERSEMBAHAN.PDF

Download (187kB) | Preview
[img]
Preview
Text (HALAMAN PERSETUJUAN)
3. HALAMAN PERSETUJUAN.PDF

Download (180kB) | Preview
[img]
Preview
Text (LEMBAR PERNYATAAN)
5. HALAMAN PERNYATAAN.PDF

Download (187kB) | Preview
[img]
Preview
Text (KATA PENGANTAR)
8. KATA PENGANTAR.PDF

Download (184kB) | Preview
[img]
Preview
Text (ABSTRAK)
10. ABSTRAKSI (BAHASA INDONESIA).PDF

Download (190kB) | Preview
[img]
Preview
Text (HALAMAN MOTTO)
6. HALAMAN MOTTO.PDF

Download (189kB) | Preview
[img]
Preview
Text (DAFTAR ISI)
9. DAFTAR ISI.PDF

Download (199kB) | Preview
[img]
Preview
Text (DAFTAR TABEL)
12. DAFTAR TABEL.PDF

Download (188kB) | Preview
[img]
Preview
Text (ABSTRAK)
11. ABSTRACT (ENGLISH LANGUAGE).PDF

Download (182kB) | Preview
[img]
Preview
Text (DAFTAR GAMBAR)
13. DAFTAR GAMBAR.PDF

Download (186kB) | Preview
[img] Text (BAB III)
17. BAB III.PDF
Restricted to Registered users only

Download (241kB) | Request a copy
[img]
Preview
Text (BAB I)
15. BAB I.PDF

Download (196kB) | Preview
[img]
Preview
Text (LAMPIRAN)
14. DAFTAR LAMPIRAN.PDF

Download (185kB) | Preview
[img] Text (BAB IV)
18. BAB IV.PDF
Restricted to Registered users only

Download (751kB) | Request a copy
[img]
Preview
Text (BAB II)
16. BAB II.PDF

Download (343kB) | Preview
[img]
Preview
Text (DAFTAR PUSTAKA)
20. DAFTAR PUSTAKA.PDF

Download (180kB) | Preview
[img]
Preview
Text (BAB V)
19. BAB V.PDF

Download (192kB) | Preview
[img]
Preview
Text (DAFTAR RIWAYAT HIDUP)
22. DAFTAR RIWAYAT HIDUP.PDF

Download (191kB) | Preview
[img]
Preview
Text (LEMBAR KONSULTASI)
24. LEMBAR KONSULTASI PENYUSUNAN SKRIPSI.PDF

Download (243kB) | Preview
[img]
Preview
Text (LEMBAR PENGAJUAN JUDUL)
23. LEMBAR PENGAJUAN JUDUL SKRIPSI.PDF

Download (244kB) | Preview
[img]
Preview
Text (LAMPIRAN)
21. LAMPIRAN.PDF

Download (1MB) | Preview
[img]
Preview
Text
25. HALAMAN PEMISAH.PDF

Download (225kB) | Preview
Official URL: http://www.library.pip-semarang.ac.id

Abstract

Air conditioner is an auxiliary machine at ship that used to cooling all accomodation room and food storage room. There needs to be maintenance for the air conditioner to work to get the required temperature, which consists of the main components and supporting components, including: Compressor, condensor, oil separator, dryer, expantion valve, evaporator, refrigerant duct system and electric control system. That components must be maintenanced consistenly according with instruction manual book. If there are abnormalities, take action immediately to prevent fatal damage. If there is little damage or unstable with the system, it will affect the cooling process. In this writing, the author uses the Fishbone method and Fault Tree Analysis by taking the causal factors and the risk of danger to the object under study. The fishbone method can be solved by human, machine, method and environmental factors. While the Fault Tree Analysis method is effective to find the core of a problem that comes from a single point of failure with a top down approach, which begins with the assumption of failure or loss from the top event. The results obtained in the study are that the factors that cause high temperatures in the air conditioner are operations that are not in accordance with predetermined standards caused by machinists do not know the standards that have been set, and the use of freon that is not in accordance with air conditioners caused by companies that wrongly sent freon supplies to the ship. Thus, this will affect the high temperature produced by the air conditioner. The effort is carried out by maintaining the supporting components of the air conditioner, including compressors, condensors and evaporators. Keywords: High temperature, circulation, freon.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: High temperature, circulation, freon.
Subjects: Skripsi
Skripsi > Teknika
Divisions: Teknika
Depositing User: Unnamed user with email dannupurwanto07@gmail.com
Date Deposited: 21 Feb 2019 07:33
Last Modified: 21 Feb 2019 07:33
URI: http://repository.pip-semarang.ac.id/id/eprint/1535